Configure Advanced Redundant Control System
ASCO Numatics Advanced Redundant Control System Configurator
Enter valid model number or use configurator below to generate a valid number.

Please Configure a model number using the attributes below
* Indicates a required attributes. 0 of 0   required attributes selected.
Model Number Generator
  141 A            
 
Connection Type
8 = NPT

Function
1 = 1oo2 Configuration, without online maintenance & without Diagnostic
2 = 1oo2 Configuration, with common by-pass & without diagnostic
3 = 2oo2 Configuration, without Online Maintenance and diagnostic
4 = 2oo2 Configuration, without Online Maintenance, with diagnostic
5 = 2oo2 Configuration, with common by-pass with diagnostic
6 = 2oo2 Configuration, with Individual Isolation with diagnostic
7 = 2oo3 Configuration, without diagnostic and online maintenance
8 = 2oo3 Configuration, without Online Maintenance, with diagnostic
A = 2oo3 Configuration, with Individual Isolation and with diagnostic

Port Size / Body Material
1 = Standard Flow-Port Size 1/4" NPT - Stainless Steel 316
2 = Standard Flow-Port Size 1/4" NPT - Aluminium
3 = Standard Flow-Port Size 1/2" NPT - Stainless Steel 316
4 = Standard Flow-Port Size 1/2" NPT - Aluminium

Voltage
H1 = 24V DC
H9 = 48V DC
HJ = 110V DC
HD = 120V DC
J1 = 125V DC
HQ = 24V/50-60HZ AC
JY = 110V/50-60HZ AC
HC = 115V/50-60HZ AC
HA = 120V/50-60HZ AC
JV = 220V/50-60HZ AC
HH = 230V/50-60HZ AC
 
Solenoid Valve
Auto Reset, Stainless Steel, Standard Temperature
0 = 327B102 - Auto reset, FPM Sealing, Normally Closed, Stainless Steel, Power 3.6/3.7W, Fluid Temperature range -20 deg C to +82 deg C
1 = 327B202 - Auto reset, FPM Sealing, Normally Closed, Stainless Steel, Power 5.7/5.8W, Fluid Temperature range -20 deg C to +82 deg C
2 = 327B302 - Auto reset, FPM Sealing, Normally Closed, Stainless Steel, Power 1.7/1.8W & Low Power IS 0.5W, Fluid Temperature range -20 deg C to +82 deg C
D = 327G042 - Auto reset, FPM Sealing, Normally Closed, Stainless Steel, Power10/11.2W, Fluid Temperature -20 deg C to +55 deg C.
H = 327H102 - Auto reset, FPM Sealing, Normally Closed, Stainless Steel, Power 3.9W, Fluid Temperature -20 degC to +90 deg C.
Manual Reset, Stainless Steel, Standard Temperature
7 = 327B132 - Tamper Proof reset, FPM Sealing, Normally Closed, Stainless Steel, Power 3.6/3.7W, Fluid Temperature range -20 deg C to +82 deg C
8 = 327B232 - Tamper Proof reset, FPM Sealing, Normally Closed, Stainless Steel, Power 5.7/5.8W, Fluid Temperature range -20 deg C to +82 deg C
9 = 327B332 - Tamper Proof reset, FPM Sealing, Normally Closed, Stainless Steel, Power1.7/1.8W, Fluid Temperature range -20 deg C to +82 deg C
F = 327G032 - Tamper Proof reset, FPM Sealing, Normally Closed, Stainless Steel, Power 10/11.2W, Fluid Temperature -20 deg C to +55 deg C.
J = 327H132 - Tamper Proof reset, FPM Sealing, Normally Closed, Stainless Steel, Power 3.9W, Fluid Temperature -20 deg C to +90 deg C.
Auto Reset, Aluminum, Standard Temperature
M = 327B103 - Auto reset, FPM Sealing, Normally Closed, Aluminun, Power 3.6/3.7W, Fluid Temperature range -20 deg C to +82 deg C.
N = 327B203 - Auto reset, FPM Sealing, Normally Closed, Aluminum, Power 5.7/5.8W, Fluid Temperature range -20 deg C to +82 deg C.
P = 327B303 - Auto reset, FPM Sealing, Normally Closed, Aluminum, Power 1.7/1.8W & Low Power IS 0.5W, Fluid Temperature range -20 deg C to +82 deg C.
Auto Reset, Stainless Steel, 307 Pilot Operated, Standard Temperature
Q = 307B005 - Pilot Operated, Auto reset, FPM Sealing, Normally Closed, Stainless Steel, Power IS 0.35W, Fluid Temperature -20 deg C to +60 deg C.

Options
A00 = No Options
Visual Indication
A01 = SS VISUAL INDICATOR
A02 = SS PRESSURE GAUGE
Digital input Feed back
B01 = Pressure Switch - Potential Free for Intrinsically Safe Wiring
B02 = Pressure Switch - Potential Free for Exproof Wiring
Manual Override
M01 = With Manual Override
Certificates
D01 = INMETRO
D02 = KOSHA
D03 = CUTR
D04 = NEPSI
D05 = PESO
 
Electrical Connection Type
Exproof. E Exd, Die Cast Aluminum Enclosure
FN = Solenoid Housing, Die Cast Aluminium, Explosion Proof with 1/2" NPT cable entry, Safety Code II2G Ex d IIC Gb T6/T5/T4, II2D, Ex t IIIC Db.ATEX/IEC Ex Certified
FT = Solenoid Housing, Die Cast Aluminium, Explosion Proof with M20 * 1.5 Cable Entry, Safety Code II2G Ex d IIC Gb T6/T5/T4, II2D, Ex t IIIC Db, ATEX/IEC Ex Certified
Exproof. E Exd, Stainless Steel Enclosure
FS = 316 Stainless Steel Water Tight Junction Box w/ Explosion proof Direct Cable Entry 1/2 NPT, Safety Code II2G Ex d IIC Gb T6/T5/T4, II2D, Ex t IIIC Db (WSNF-IECEx), ATEX/IEC Ex Certified
FU = Solenoid Housing, Stainless Steel, Explosion Proof with M20 * 1.5 cable entry, Safety Code II2G Ex d IIC Gb T6/T5/T4, II2D, Ex t IIIC Db, (WSNF-IEC Ex), ATEX/IEC Ex Certified
WR = Solenoid Housing, Stainless Steel, Explosion Proof with 1/2 NPT Cable Entry, Safety Code II2G Ex d IIC Gb T6/T5/T4, II2D, Ex t IIIC Db, (WSCR-IEC Ex), ATEX/IEC Ex Certified
X2 = Solenoid Housing, Stainless Steel, Explosion Proof with M20 * 1.5 cable entry, Safety Code II2G Ex d IIC Gb T6/T5/T4, II2D, Ex t IIIC Db, (WSCR-IEC Ex), ATEX/IEC Ex Certified
Intrinsically Safe. E Exia, Die Cast Aluminum Enclosure
F1 = Solenoid Housing, Die Cast Aluminium, Intrinsically Safe with 1/2 NPT Cable Entry, Safety Code II2G Ex ia IIC Gb T6, II2D, Ex t IIIC Db (Standard Flow Only), ATEX/IEC Ex Certified
X1 = Solenoid Housing, Die Cast Aluminium, Intrinsically Safe with M20 * 1.5 Cable Entry, Safety Code II2G Ex ia IIC Gb T6, II2D, Ex t IIIC Db (Standard Flow Only), ATEX/IEC Ex Certified
Intrinsically Safe. E Exia, Stainless Steel Enclosure
X3 = Solenoid Housing, Stainless Steel, Intrinsically Safe with 1/2 NPT Cable Entry, Safety Code II2G Ex ia IIC Gb T6, II2D, Ex t IIIC Db (Standard Flow Only), ATEX/IEC Ex Certified
X4 = Solenoid Housing, Stainless Steel, Intrinsically Safe with M20 * 1.5 Cable Entry, Safety Code II2G Ex ia IIC Gb T6, II2D, Ex t IIIC Db (Standard Flow Only), ATEX/IEC Ex Certified
X5 = Solenoid Housing, Stainless Steel, Intrinsically Safe with 1/2 NPT Cable Entry, Safety Code II2G Ex ia IIC Gb T6, II2D, Ex t IIIC Db (Standard Flow Only), CCOE
X6 = Solenoid Housing, Stainless Steel, Intrinsically Safe with M20 * 1.5 Cable Entry, Safety Code II2G Ex ia IIC Gb T6, II2D, Ex t IIIC Db (Standard Flow Only), CCOE
Encapsulated with Exd protection, E Ex d m, Die Cast Aluminum Enclosure
VA = Solenoid Housing, Die Cast Aluminium, Explosion Proof with 1/2 NPT Cable Entry, Safety Code II2G Ex d m IIC Gb T6/T5/T4, II2D, Ex t IIIC Db (Standard Flow Only), Top Cable Entry, ATEX/IEC Ex Certified
VB = Solenoid Housing, Die Cast Aluminium, Explosion Proof with M20*1.5 Cable Entry, Safety Code II2G Ex d m IIC Gb T6/T5/T4, II2D, Ex t IIIC Db (Standard Flow Only), Top Cable Entry, ATEX/IEC Ex Certified
Increased Safety E Ex e mb, Enclosure
MV = Solenoid Housing, Steel with, Increased Safety with 1/2"NPT Cable Entry, Safety Code: II2G Ex e mb IIC Gb T6/T5, II2D Ex tb IIIC Db, ATEX/IEC Ex Certified
MT = Solenoid Housing, Steel with, Increased Safety with M20 *1.5 Cable Entry, Safety Code: II2G Ex e mb IIC Gb T6/T5, II2D Ex tb IIIC Db, ATEX/IEC Ex Certified
X7 = Solenoid Housing, Stainless Steel with, Increased Safety with 1/2"NPT Cable Entry, Safety Code: II2G Ex e mb IIC Gb T6/T5, II2D Ex tb IIIC Db, ATEX/IEC Ex Certified
X8 = Solenoid Housing, Stainless Steel with, Increased Safety with M20 *1.5 Cable Entry, Safety Code: II2G Ex e mb IIC Gb T6/T5, II2D Ex tb IIIC Db, ATEX/IEC Ex Certified
Weather Proof Protected Enclosure
X9 = Waterproof IP67 - with M20*1.5 Cable Gland, Metal enclosure
XA = Waterproof IP67 - M20*1.5 Cable Entry, Metal enclosure
XC = Waterproof IP67 - with M20*1.5 Cable Gland, Stainless Steel enclosure
XD = Waterproof IP67 - with M20*1.5 Cable Entry, Stainless Steel enclosure
XE = Waterproof IP67 - 1/2"NPT Cable Entry, Metal enclosure
XF = Waterproof IP67 - with 1/2"NPT Cable Entry, Stainless Steel enclosure
S1 = Spade plug connector (EN/IEC 60730), IP65